Ideally, when we design or redesign your website, we would prefer to Host it. We know how our servers work with interactive forms, etc. Additionally, our online content management solution works only with our Web Hosting services. However, if you have a Web Hosting account already, and you prefer to continue to Host with them, we are flexible and have no issues with not Hosting the website. Also, if you wish to keep your email where it currently is, but want us to Host your website, we have solutions for this as well.

To register a Domain through our partner site with NameBargain.com, click here (Domains from $9.99 per year). All of our monthly service customers have one Domain name registration or transfer included. Transfer must be completed in order to be included in the monthly service.

Data Center Specifications

We have multiple cabinets at our Data Center in Carson City, NV. We maintain a fully redundant, enterprise class network, end- to- end. At our Data Center facility, we have over 4,000 square feet of raised floor, and another 2,500 square feet of office space to support our day-to-day business operations, and on-site staff.

Power

Located in Nevada's central business district, the building we occupy has power feeds from multiple substations.  We deliver smooth filtered power to the Data Center without small interruptions. In the event of a power failure, our diesel generator will immediately start up, and begin carrying the entire Data Center load. Building life safety systems are backed up by two separate generators.

Environmental

Cooling and humidity is controlled by 7 air handling units, featuring N+1 redundancy.  Operating environment in the Data Center is kept at 70 degrees within 45% humidity, with variation of no more than 4 degrees in temperature and 4% humidity. To ensure that optimal cooling and air circulation is available at all times, air flow studies are conducted and an analysis with infrared heat sensing cameras is performed on a regular basis. We also have local and remote environmental monitoring systems in place.

Security

Our Data Center facility is located in a building that has 24/7 On-site Security. After business hours, all individuals entering or exiting the building are required to present building credentials, and sign in with On-site Security staff. Upon doing so, they are only granted elevator access to the floor they need access to. Additionally, we have our own Security system which consists of access control systems within our office suite, and remotely monitored video surveillance.

Fire Detection & Suppression

Fire detection within the Data Center is provided by an Early Detection Alarm System, monitored both within our office suite, and by the building's 24/7 security staff. The Data Center has detectors installed both above and below the raised flooring. The Fire Suppression system is a pre-action, dry pipe which would discharge, only from the appropriate locations. The discharge of a sprinkler would signal the emergency power-off switch, which would simultaneously turn off the commercial electrical power, and switch to UPS power.

Intrusion Detection / Network Security

Our entire network is protected by redundant, inline TopLayer IPS 5500-1000 units. The TopLayer IPS 5500s are the only Intrusion System protection to ever receive a coveted double NSS approved award in a single test. This provides protection against malicious content through advanced IPS technology, against undesired access through stateful firewall filtering, and against rate-based attacks through DDoS mitigation.

Monitoring

All critical network infrastructure is Monitored on 60-second intervals, both internally and externally to our network. Any potential issues with our network infrastructure are immediately escalated to company management.